APT 3100

APT 3100 Smart Pressure Transmitter

APT-3100-Smart-Pressure-Transmitter

The APT 3100 Smart Pressure Transmitter is a microprocessor-based high-performance transmitter, which has flexible pressure calibration. The APT 3100 pressure transmitter is a microprocessor-based high performance trans 1 meter with flexible pressure calibration and output capabilities, automatic compensation of ambient temperature and process variable, the configuration of various parameters and communication with HART communication can max 1.5km in multi-drop mode, max application areas include: measuring pressure flow and level.

Function

  • Type: Pressure- Differential(DPIT), Gauge/ Absolute(PIT), Level(LIT), High Static Pressure, Flow Pressure(FIT)
  • Certificate: SIL2 (TUV, FMEDA), Ex d, Ex ia, FM, ATEX, TR CU(EAC), INMETRO, CE, Rohs, BV, LR, KR, DNV, ABS, KCs, IP66/67, NEMA 4X
  • Feature: 4 to 20mA, HART, Loop Powered
  • Accuracy: ± 0.075% (option ± 0.04%) of CS* 3 lines LCD display, Self Diagnostic Function, External Buttons, DAC, Zero Trim, Eng mode
  • Application: Pressure, Flow, Level measurement for Oil & Gas, Liquid, Water, Maine & offshore, Vessel, Power, Chemical Plants and Refinery
  • Flexible Absolute Pressure Sensor input.
  • Working Pressure Limits (silicone oil):
    – 0 to 400 kPa for Range 4
    – 0 to 1500 kPa for Range 5
    – 0 to 3000 kPa for Range 6
  • Hydrostatic Test Pressure:
    – Range 4: 58 psi (400 kPa)
    – Range 5:218 psi (1500 kPa)
    – Range 6: 435 psi (3000 kPa)
  • Burst Pressure: 2000 psig (13.8 MPa)
  • Output: 4 ~20mA (Analog), Digital Signals
  • High Accuracy: ±0.075% of Span (at 20°C)
  • High Rangeability (100:1)
  • Automatic Compensation of Ambient Temperature
  • Programmable Parameters: Zero/Span, Fail-mode, Unit, Trim, etc
  • Digital communication with HART protocol, command.
  • 5 Digit LCD

Model Name: APT3100
Protocol: 4 to 20mA + Digital Communication, HART 5
Trim ability: Zero, DAC, FULL
Power supply & Load Requirement: 250 to 550 ohm @ 24 Vdc, Loop Powered
Failure Mode: Low ≤ 3.78 mA, High ≥ 21.1 mA
External Buttons: Zero & Span 2 buttons for device configuration
Process Temp. limit: -40 to 120℃ ( -104 to 248℉ )
Range Ability: 100:1
Stability: ±0.125% URL for 36 months